Company Name : Joyjeet Das Memorial Foundation and Educational Trust IIATCA and IIATEA (iiatca.org)
Training Offered : Summer and Winter Vocational Training on PLC & SCADA
Location : Kolkata
Website : http://www.iiatca.org/
Training :
Summer and Winter Vocational Training on PLC & SCADA :
Evaluated and certified by IIATCA
Course Details :
** PLC Hardware fundamentals
** Ladder Logic Concepts
** Real life control components identification and conventional electrical wiring
** through various applications
** Use of PLC programming softwares through few basic applications
** Introduction on SCADA softwares
** Creating a basic project on SCADA
** A small project on Automation with PLC and SCADA
Course Fees : Rs3,500/-
Course duration : 1 Month ( Five days a week)
Course Modules : 20 (Each module is of 3 Hrs)
Course Type : In groups
Basic Industrial Electrical : Course Code Ie 01
Evaluated and Certified by IIATEA
Course Details :
Identification of Single and Three phase circuits, Familiarization with various types of earthing systems like resistance, neutral earthing & difference between pipe & plate earthing, Familiarization with various types of measuring instruments like Multimeter (Digital & Analog) , Tong tester/ Clamp meter, Ammeters with & without CT, Voltmeter with & without P.T.,
Preparation of a diagram & completing a wiring of D.O.L starter with overload trip for a 3ph Induction Motor. Preparation of a diagram & completing a Star Delta Starter with Overload trip for the same motor
Equipment sizing calculations, Transformer sizing calculation, CT & PT sizing calculation, Battery sizing calculation etc.
Course fees : Rs 4000/- nett
Course duration : 10 Modules (Each module is of 4 Hrs)
Maximum duration : 15 Days
Course Type : Individually Cared
Process Instrumentation :
Name : Installation, Repair and Maintenance of Temperature Measuring Instruments
Sector : Process Instrumentation
Course Code : PRO105
Duration : 80 Hours
Terminal Competence :
** This course is connected with temperature measurement sensors and Calibration.
** On Completion of the module, the trainees will be able to do Installation various thermometer form -0 degree C to 1000 degree C as per ITC 90 scale. Installation and connection of thermocouple & RTD for temperature measurement. Calibration and error compensation of
** Thermocouple and RTD.
** Develop some physical analogies
Contact Us :
Joyjeet Das Memorial Foundation and Educational Trust
IIATCA and IIATEA
DA – 169, Sector I,
Salt Lake,
Kolkata – 700 064,
West Bengal, India